Hydrometer Temperature Correction Calculator

Adjust your hydrometer reading for temperature to get the true specific gravity.

How it is calculated

The tool uses the density of water at the two temperatures, taken from a third-degree polynomial in degrees Fahrenheit, as the correction factor:

f(T) = 1.00130346 − 0.000134722124·T + 0.00000204052596·T² − 0.00000000232820948·T³

corrected gravity = measured gravity × f(sample temp) / f(calibration temp)

Both temperatures are in °F. The sample temperature is the real temperature of the liquid in the cylinder, and the calibration temperature is printed on your hydrometer (often 60 °F or 68 °F). The result is shown with three decimals. If the two temperatures are equal, the reading comes back unchanged. The tool does not check the temperatures against the freezing and boiling point of water, so an unrealistic entry still returns a number. The correction is for the density change of water-like wort and must; it is not an alcohol or sugar correction.

Worked example

You read 1.050 on a hydrometer calibrated at 60 °F, but the wort sample is at 80 °F.

f(80) ≈ 1.00239 and f(60) ≈ 1.00006, so the ratio is about 1.0023.

Corrected gravity = 1.050 × 1.0023 ≈ 1.052.

The warm sample read a little low, so the true gravity at 60 °F is slightly higher than the reading.

Try this example →

Common mistakes

  • Entering Celsius temperatures. A 25 °C sample typed as 25 and a 15.6 °C calibration typed as 15.6 are read as 25 °F and 15.6 °F, giving a silently wrong answer (1.049 instead of 1.052). Convert to °F first.
  • Typing the gravity as 1050 or 50 instead of 1.050. The field expects the specific gravity, so 1050 returns 1,052.446.
  • Entering the temperature of the room or of the fermenter instead of the liquid in the test jar, which is the one that matters.
  • Entering the wrong calibration temperature. Hydrometers differ (60 °F or 68 °F), so check the scale or the box.
  • Applying the correction twice, or to a reading that was already taken at the calibration temperature, when the tool's answer would just return the same figure.

About this calculator

Hydrometers are calibrated to give accurate specific-gravity readings only at one reference temperature — commonly 60°F (15.6°C) or 68°F (20°C) depending on the instrument — because liquid expands as it warms, becoming less dense, which makes a hot sample read artificially low and a cold sample read artificially high compared to its true gravity at the calibration temperature. The correction applies a temperature-adjustment formula (or lookup table) based on the difference between the sample's actual temperature and the hydrometer's calibration temperature to recover the true specific gravity.

Homebrewers and winemakers take this correction seriously because specific gravity readings taken before and after fermentation are used to calculate alcohol content and track fermentation progress, and an uncorrected reading taken from a warm wort or must sample can throw off both the tracked attenuation and the final ABV calculation. It's a standard step any time gravity is checked with a wort or must sample straight out of the kettle or fermenter rather than cooled to the hydrometer's reference temperature.