QUICKI Insulin Sensitivity Calculator
Enter fasting insulin and glucose to get the QUICKI index.
Result
How it is calculated
Enter fasting insulin in µU/mL and fasting glucose in mg/dL, both from the same blood sample. The tool applies QUICKI = 1 / (log10(insulin) + log10(glucose)) and shows the index with four decimals. A higher index means better insulin sensitivity, and a lower one means greater insulin resistance.
Both inputs must be above zero, because a logarithm needs a positive number, and insulin × glucose must be above 1; at 1 or less the two logarithms add up to zero or less and the tool shows no result. The tool does no unit conversion: glucose in mmol/L would give a misleadingly high index, since the formula is built for mg/dL. It returns a number only and does not label it normal or abnormal, and it cannot replace a clinician’s interpretation. Cut-offs vary by laboratory and population, and the values are valid only for a fasting sample.
Worked example
Fasting insulin 10 µU/mL and fasting glucose 90 mg/dL. The base-10 logarithm of 10 is 1.0000, and the logarithm of 90 is 1.9542. Add them: 1.0000 + 1.9542 = 2.9542. Take the reciprocal: 1 / 2.9542 = 0.3385. For comparison, insulin 20 with glucose 100 gives 0.3029, a lower value that points to greater insulin resistance.
Common mistakes
- Entering glucose in mmol/L. A value of 5 instead of 90 mg/dL gives an index around 0.59, outside the usual range, so multiply mmol/L by about 18 first.
- Using a non-fasting sample. Insulin and glucose both rise after eating, which lowers the index and makes sensitivity look worse than it is.
- Entering insulin in pmol/L instead of µU/mL. The numbers differ by a factor of roughly six, so the result will be wrong.
- Mixing up the direction. A higher QUICKI is better sensitivity, the opposite of HOMA-IR, where a higher value means more resistance.
- Using the index as a diagnosis. It is a single calculated number, and it needs a clinician to interpret it alongside other tests.
Sources
- Quantitative insulin sensitivity check index: a simple, accurate method for assessing insulin sensitivity in humans — J Clin Endocrinol Metab, 2000
About this calculator
QUICKI (Quantitative Insulin Sensitivity Check Index) is computed as 1 / [log₁₀(fasting insulin, µU/mL) + log₁₀(fasting glucose, mg/dL)], a log-transform that linearizes the otherwise skewed relationship between insulin and glucose so the index behaves more predictably across a population. Values typically fall between about 0.30 and 0.45, with lower numbers indicating greater insulin resistance.
Because it needs only a single fasting blood draw rather than the multi-hour, multi-sample hyperinsulinemic-euglycemic clamp considered the gold standard, endocrinologists and metabolic researchers use QUICKI (alongside HOMA-IR) as a practical outpatient screening tool for insulin resistance and early type 2 diabetes risk.
Was this helpful?
You can pick up to 3 reactions.
Popular calculators
Loan Calculator
Monthly payment, total interest and full amortization schedule.
Percentage Calculator
Percent change, percent of, and ratio calculations.
Discount Calculator
Calculate final price, savings, and discount amount.
BMI Calculator
Body mass index from height and weight (metric or imperial).
Age Calculator
Compute your exact age in years, months and days from a birth date.
Compound Interest Calculator
Calculate the final amount and interest earned with compounding.
All Calculators
- Loan Calculator
- Profit Calculator
- Discount Calculator
- BMI Calculator
- Percentage Calculator
- Ideal Weight Calculator
- Age Calculator
- Pregnancy Due Date Calculator
- Compound Interest Calculator
- BMR Calculator (Basal Metabolic Rate)
- Tip Calculator
- Fuel Cost Calculator
- Date Difference Calculator
- Sleep Cycle Calculator
- Daily Water Intake Calculator
- Simple Interest Calculator
- Heart Rate Zones Calculator
- Running Pace Calculator
- Pet Age Calculator
- Calories Burned Calculator
- Macro Calculator
- TDEE Calculator (Total Daily Energy Expenditure)
- Waist-to-Hip Ratio Calculator
- Honor Roll Calculator
- One Rep Max (1RM) Calculator
- Ovulation Calculator
- Electricity Cost Calculator
- Unit Price Calculator
- Savings Goal Calculator
- Break-Even Point Calculator
- Paint Calculator
- Course Grade Average Calculator
- Business Days Calculator
- Time Duration Calculator
- Fuel Economy Calculator
- Temperature Converter
- Tile Calculator
- Aspect Ratio Calculator
- Roman Numeral Converter
- Goal Weight Timeline Calculator
- Salary Converter (Hourly to Annual)
- Credit Card Validator (Luhn)
- Body Surface Area (BSA) Calculator
- Feels-Like Temperature Calculator
- Ohm’s Law Calculator
- PPI (Pixel Density) Calculator
- Molar Mass Calculator
- Zodiac Sign Calculator (Western + Chinese)
- IBAN Validator
- Shoe Size Converter
- Country Info & Dialing Code Lookup
- Time Zone Difference (World Clock)
- CAGR (Compound Annual Growth Rate) Calculator
- Rule of 72 Calculator
- Blood Alcohol Content (BAC) Calculator
- Lean Body Mass (LBM) Calculator
- Pythagorean Theorem Calculator
- Speed Converter
- Download Time Calculator
- Date Calculator (Add/Subtract)
No calculators found
Comments (1)
Because the formula uses logarithms, the index moves slowly. At a glucose of 90, doubling insulin from 10 to 20 only lowers it from 0.3385 to 0.3072, so small differences between two results are small changes. Lab values also vary from one draw to the next. Your own clinician should interpret any number. Which lab units does your report use for insulin and glucose?